Thank you for choosing DELTA’s high-performance VFD-F Series. The VFD-F Series is
manufactured with high-quality components and materials and incorporates the latest microprocessor
technology available.
Getting Started
This quick start will be helpful in the installation and parameter setting of the AC motor drives. To
guarantee safe operation of the equipment, read the following safety guidelines before
connecting power to the AC motor drives. For detail information, refer to the VFD-F User Manual
on the CD supplied with the drive.
DANGER!
1. AC input power must be disconnected before any wiring to the AC motor drive is made.
2. A charge may still remain in the DC-link capacitors with hazardous voltages, even if the power
has been turned off. To prevent personal injury, please ensure that power has turned off before
opening the AC motor drive and wait ten minutes for the capacitors to discharge to safe voltage
levels.
3. Never reassemble internal components or wiring.
4. The AC motor drive may be destroyed beyond repair if incorrect cables are connected to the
input/output terminals. Never connect the AC motor drive output terminals U/T1, V/T2, and
W/T3 directly to the AC mains circuit power supply.
5. Ground the VFD-F using the ground terminal. The grounding method must comply with the laws
of the country where the AC motor drive is to be installed. Refer to the Basic Wiring Diagram.
6. VFD-F series is used only to control variable speed of 3-phase induction motors, NOT for 1-
phase motors or other purpose.
7. VFD-F series shall NOT be used for life support equipment or any life safety situation.
WARNING!
1. DO NOT use Hi-pot test for internal components. The semi-conductor used in AC motor drive
easily damage by high-pressure.
2. There are highly sensitive MOS components on the printed circuit boards. These components
are especially sensitive to static electricity. To prevent damage to these components, do not
touch these components or the circuit boards with metal objects or your bare hands.
3. Only quality person is allowed to install, wire and maintain AC motor drive.
CAUTION!
1. Some parameters settings can cause the motor to run immediately after applying power.
2. DO NOT install the AC motor drive in a place subjected to high temperature, direct sunlight,
high humidity, excessive vibration, corrosive gases or liquids, or airborne dust or metallic
particles.
3. Only use AC motor drives within specification. Failure to comply may result in fire, explosion or
electric shock.
4. To prevent personal injury, please keep children and unqualified people away from the
equipment.
5. When the motor cable between AC motor drive and motor is too long, the layer insulation of the
motor may be damaged. Please use a frequency inverter duty motor or add an AC output
reactor to prevent damage to the motor. Refer to appendix B Reactor for details.
6. The rated voltage for AC motor drive must be 240V (480V for 460V models) and the mains
supply current capacity must be 5000A RMS (10000A RMS for the 40hp (30kW) models).
Seitenansicht 0
1 2 3 4 5 6 ... 30 31

Inhaltsverzeichnis

Seite 1 - Preface

English-1 Preface Thank you for choosing DELTA’s high-performance VFD-F Series. The VFD-F Series is manufactured with high-quality components and mate

Seite 2 - Specifications

English-10 150HP (VFD1100F43A) POWER IM3MOTORV/T2S/L2R/L1 +2+1T/L3 U/T1 W/T3 150 HP to 215 HP (VFD1100F43C, VFD1320F43A, VFD1600F43A) POWER DC(+)I

Seite 3 - 485 communication

English-11 250 HP to 300 HP (VFD1850F43A, VFD2200F43A) DC + DC ( )( )-POWER U/T1T/L3R/L1 S/L2+-W/T3V/T2 Terminal Explanations Terminal Symbol Explan

Seite 4 - English-4

English-12 Control Terminals Explanations Terminal Symbols Terminal Functions Factory Settings FWD Forward-Stop command REV Reverse-Stop command

Seite 5 - To modify data

English-13 SUMMARY OF PARAMETER SETTINGS a: The parameter can be set during operation Group 0 AC Drive Status Parameter Parameter Functions Settings

Seite 6 - KPF-CC01

English-14 Parameter Functions Settings Factory SettingCustomer Bit 9: Master frequency source via analog Bit10: Running command via communicatio

Seite 7 - English-7

English-15 Parameter Functions Settings Factory SettingCustomera01-14 Deceleration Time 3 0.1~3600.0 Sec 10.0/60.0 a01-15 Acceleration Time 4

Seite 8 - English-8

English-16 Parameter Functions Settings Factory SettingCustomer02-04 Forward/Reverse Enable 00: Forward enabled 01: Reverse disabled 02: Forward dis

Seite 9 - English-9

English-17 Parameter Functions Settings Factory SettingCustomer03-05 Multi-function Output terminal 6 00 03-06 Multi-function Output terminal 7 00

Seite 10 - English-10

English-18 Group 4 Input Function Parameters Parameter Functions Settings Factory SettingCustomer04-00 Multi-function Input terminal 1 01 04-01 Mul

Seite 11 - English-11

English-19 Parameter Functions Settings Factory SettingCustomer04-19 ACI2 Minimum frequency (percentage of Pr.1-00) 0.00~100.00% 0.00 04-20 ACI2 M

Seite 12 - English-12

English-2 Specifications Voltage Class 230V Class Model Number VFD-XXXF23X 007 015 022 037 055 075 110 150 185 220 300 370Max. Applicable Motor Out

Seite 13 - English-13

English-20 Parameter Functions Settings Factory SettingCustomera05-14 15th Step Speed Frequency 0.00~120.00 Hz 0.00 05-15 PLC Mode 00: Disable

Seite 14 - English-14

English-21 Parameter Functions Settings Factory SettingCustomer06-03 Over-torque Detection Selection 00: Over-torque detection disabled. 01: Over-t

Seite 15 - English-15

English-22 Parameter Functions Settings Factory SettingCustomer 23: Lc (Low Current) 24: Fbl (Feedback Loss) 25: Reserved 26: FAnP (Fan Power Fau

Seite 16 - English-16

English-23 Parameter Functions Settings Factory SettingCustomer08-02 DC Brake Time during Stopping 0.00~60.00 Sec 0.0 08-03 Start-point for DC

Seite 17 - English-17

English-24 Parameter Functions Settings Factory SettingCustomera09-02 Transmission Fault Treatment 00: Warn and keep operating 01: Warn and RAMP to

Seite 18 - English-18

English-25 Group 10 PID Controls Parameter Functions Settings Factory SettingCustomer10-00 Input Terminal for PID Feedback 00: No function 01: Inpu

Seite 19 - English-19

English-26 Parameter Functions Settings Factory SettingCustomer11-06 Motor Switch Frequency during Fixed Amount Circulation 0.00 to 120.00 Hz 60.00

Seite 20 - English-20

English-27 Fault Name Fault Descriptions Corrective Actions Overheating Heat sink temperature too high 1. Ensure that the ambient temperature falls

Seite 21 - English-21

English-28 Fault Name Fault Descriptions Corrective Actions Over-current during steady state operation 1. Short-circuit at motor output: Check for

Seite 22 - English-22

English-29 Fault Name Fault Descriptions Corrective Actions Fan 2 fault (150~300HP) Remove any foreign objects on the heatsinks and check for possib

Seite 23 - English-23

English-3 General Specification Other Functions AVR, 2 kinds of S-Curve, Over-Voltage, Over-Current Stall Prevention, Fault Records, Reverse inhibitio

Seite 24 - English-24

English-30 DACBE Model Name A B C D E F 370F43A, 450F43A, 550F43A 370.0 [14.57]589.0 [23.19]260.0 [10.24] 335.0 [13.19]560.0 [22.05]13.0 [0.51]

Seite 25 - English-25

English-31 FWDVFD-PU01 DATASTOPRESETRUNSTOPUFHRUNJOGJOG REVMODEPROG Model Name A B C D E F G 1100F43C, 1320F43A, 1600F43A 425.0 [16.73] 850.0 [

Seite 26 - Fault Codes

English-4 For 230V series, 20hp and above models 460V series, 25hp and above models JumperDC Reactor(Optional)BrakeResistor(Optional)PNB1B2VFDBBr

Seite 27 - English-27

English-5 Y Operation steps of the Digital Keypad VFD-PU01 MODEMODEMODEMODEMODEMODE STARTUFHSelecting mode STARTTo shift dataTo modify dataSetting dir

Seite 28 - English-28

English-6 KPF-CC01 X Description of the Digital Keypad KPF-CC01 LCD DisplayIndicates frequency, voltage, current, userdefined units, read, and save et

Seite 29 - English-29

English-7 Power Terminals and Control Terminal 1HP to 5HP (VFD007F23A/43A, VFD015F23A/43A, VFD022F23A/43A, VFD037F23A/43A) +1+2B1-B2R/L1 S/L2 T/L3Scr

Seite 30 - English-30

English-8 20 HP to 40 HP (VFD150F23A, VFD185F23A/43A, VFD220F23A/43A, VFD300F43A) W/T3V/T23IMPOWER S/L2R/L1- ( ) ( ) + DC DC T/L3+1-+2MOTOR 50 HP t

Seite 31 - English-31

English-9 40 HP to 125 HP (VFD300F23A, VFD370F23A, VFD550F43A, VFD750F43A, VFD900F43C) W/T3S/L2R/L1 T/L3 +2+1 U/T1 V/T2(173in-lbf)Screw Torque:200kgf