Seitenansicht 163
Appendix B Accessories|VFD-S Series
Revision August 2008, SE09, SW V2.61 B-7
If the length is too long, the stray capacitance between cables will increase and may
cause leakage current. It will activate the protection of over current, increase leakage
current or not insure the correction of current display. The worst case is that AC motor
drive may damage.
If more than one motor is connected to the AC motor drive, the total wiring length is the
sum of the wiring length from AC motor drive to each motor.
B.2.1 Dimensions
Dimensions are in millimeter and (inch)
Order P/N: RF007S21AA/ RF007S43AA
60
(2.36)
200
(7.87)
85
(3.35)
200
(7.87)
50
(1.97)
27
(1.06)
24
(0.94)
15
(0.52)
4.5
(0.18)
213
(8.39)