5.11 Group 10: Speed Feedback Parameter
10-00 PG (encoder) Pulses Factory setting 600
Settings 1~20000
This parameter sets the encoder pulse per revolution.
10-01 Encoder Input Setting (channel 1) Factory setting 0
Settings
Phase A leads in a forward run command and phase B leads in a
reverse run command. (rising/falling edge trigger) (Pulses x 4)
FWD REV
0
A
B
Phase B leads in a forward run command and phase A leads in a
reverse run command. (rising/falling edge trigger) (Pulses x 4)
FWD REV
1
A
B
Phase A is a pulse input and phase B is a direction input.
(low input = reverse direction, high input = forward direction)
FWD REV
2
A
B
Phase A is a pulse input and phase B is a direction input.
(low input = forward direction, high input = reverse direction)
FWD REV
3
A
B
Phase A is a forward run pulse, then phase B is High.
Phase B is a reverse run pulse, then phase A is High.
FWD REV
4
A
B