1 TPEditor Operation
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
1-43
on the screen. Please note that if the Device Value is smaller than 100, no picture will display as the
users do not specify its Current State and display picture. The setting range value of Current State 0
should be the greater than the setting range value of Current State 1, the setting range value of Current
State 1 should be the greater than the setting range value of Current State 2, the setting range value of
Current State 2 should be the greater than the setting range value of Current State 3, and vise versa.
Step 5. When the users double click the field of “Device Value >= Range Value” by using the mouse, the
following All States Table tab shown in Figure 1-77 will open for the users to set the setting range
values of all states.
Figure 1-77
Step 6. After pressing Refer Value button, the following Edit Range Calculator tab (Figure 1-78) will appear and
it could help to calculate the setting range value for all states.
Figure 1-78
Step 7. Click View(V) > Object Inspector command from the menu bar, a Property tab will show up on the
screen and display all the properties of the Dynamic Bitmap object. The users also could change the
settings of the Dynamic Bitmap object directly by using the drop-down lists in Property tab.