1 TPEditor Operation
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
1-48
Step 5. The Message Display Setting tab is similar to Word Lamp Setting tab. Some options are even the same,
such as Refer Device, Value Type and Value Length, etc. But in Message Display Setting tab, the Total
States could be set up to 255, i.e. from 0 to 254. Each state should have its corresponding message
text. The state of the Message Display object changes, and the corresponding message text changes
as well. The option of “Device Value >= Range Value” is used to set the corresponding setting range.
For example, suppose that Display Sequence is set to “From Max to Min”, if the setting of “Device
Value >= Range Value” is set to 300 for Current State 0, and the setting of “Device Value >= Range
Value” is set to 100 for Current State 1, when the Device Value is equal to or greater than 300, the
picture of Current State 0 will show on the screen; when the Device Value is equal to or greater than
100, the picture of Current 1 will show on the screen. Please note that if the Device Value is smaller
than 100, no picture will display as the users do not specify its Current State and display picture. The
setting range value of Current State 0 should be the greater than the setting range value of Current
State 1, the setting range value of Current State 1 should be the greater than the setting range value of
Current State 2, the setting range value of Current State 2 should be the greater than the setting range
value of Current State 3, and vise versa.
Step 6. When the users double click the field of “Device Value >= Range Value” by using the mouse, the
following All States Table tab shown in Figure 1-87 will open for the users to set the setting range
values of all states.
Figure 1-87
Step 7. After pressing Refer Value button, the following Edit Range Calculator tab (Figure 1-88) will appear and
it could help to calculate the setting range value for all states.