1 TPEditor Operation
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
1-58
Step 3. The Multi-State Bitmap Setting tab is similar to Word Lamp Setting tab. Some options are even the
same, such as Refer Device, Value Type and Value Length, etc. But in Multi-State Bitmap Setting tab,
the Total States could be set up to 255, i.e. from 0 to 254. After double-clicking the selected object, a
Open dialog box will appear and the users could select the desired display picture (the picture must be
a BMP file). Each state should have its corresponding input text. The state of the Multi-State
Bitmap/Label object changes, and the corresponding input text changes as well. The option of “Device
Value >= Range Value” is used to set the corresponding setting range. For example, suppose that
Display Sequence is set to “From Max to Min”, if the setting of “Device Value >= Range Value” is set to
300 for Current State 0, and the setting of “Device Value >= Range Value” is set to 100 for Current
State 1, when the Device Value is equal to or greater than 300, the picture of Current State 0 will show
on the screen; when the Device Value is equal to or greater than 100, the picture of Current 1 will show
on the screen. Please note that if the Device Value is smaller than 100, no picture will display as the
users do not specify its Current State and display picture. The setting range value of Current State 0
should be the greater than the setting range value of Current State 1, the setting range value of Current
State 1 should be the greater than the setting range value of Current State 2, the setting range value of
Current State 2 should be the greater than the setting range value of Current State 3, and vise versa.
Step 4. When the users double click the field of “Device Value >= Range Value” by using the mouse, the
following All States Table tab shown in Figure 1-102 will open for the users to set the setting range
values of all states.
Figure 1-102
Step 5. After pressing Refer Value button, the following Edit Range Calculator tab (Figure 1-103) will appear
and it could help to calculate the setting range value for all states.