Delta Electronics VFD-L Series Spezifikationen Seite 93

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 134
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 92
7
VFD-M Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
7-1
CHAPTER 7 TROUBLESHOOTING AND FAULT INFORMATION
The AC drive has a comprehensive fault diagnostic system that includes several different
alarms and fault messages. Once a fault is detected, the corresponding protective functions
will be activated. The following faults are displayed as shown on the AC drive digital keypad
display. The three most recent faults can be read on the digital keypad display by viewing
Pr.73 to Pr.75
NOTE: faults can be cleared by resetting at the keypad or with Input Terminal.
Common Problems and Solutions:
Fault
Name
Fault Descriptions
Corrective Actions
The AC drive detects an
abnormal increase in current.
1. Check whether the motors horsepower
corresponds to the AC drive output power.
2. Check the wiring connections between the
AC drive and motor for possible short
circuits.
3. Increase the Acceleration time (Pr.10,
Pr.12).
4. Check for possible excessive loading
conditions at the motor.
5. If there are any abnormal conditions when
operating the AC drive after short-circuit
being removed, it should be sent back to
manufacturer.
The AC drive detects that the
DC bus voltage has exceeded
its maximum allowable value.
1. Check whether the input voltage falls within
the rated AC drive input voltage.
2. Check for possible voltage transients.
3. Bus over-voltage may also be caused by
motor regeneration. Either increase the
decel time or add an optional braking
resistor.
4. Check whether the required braking power is
within the specified limits.
Seitenansicht 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 133 134

Kommentare zu diesen Handbüchern

Keine Kommentare