5
VFD-S Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-7
1 - 06 Minimum kimeneti feszültség (Vmin) Factory Setting: d12.0*
Settings d 2.0 to d 255V* Unit: 0.1V*
*Twice value for 460V class
! This parameter sets Minimum Output Voltage of the AC drive. This parameter must be
equal to or less than Mid-Point Voltage (Pr.1-04).
Voltage
Pr.1-02
Pr.1-04
Pr.1-06
0
Pr.1-03
Pr.1-05
Pr.1-00
Pr.1-01
Freq.
Standard V/F Curve
1 - 07 Upper Bound of Output Frequency Factory Setting: d 100
Settings d 1 to d110% Unit: 1%
! This parameter must be equal to or greater than the Lower Bound of Output Frequency
(Pr.1-08). The Maximum Output Frequency (Pr.1-00) is regarded as 100%.
1 - 08 Lower Bound of Output Frequency Factory Setting: d 0
Settings d 0 to d100% Unit: 1%
! The Upper/Lower Bound is to prevent operation error and machine damage.
! If the Upper Bound of Output Frequency is 50Hz and the Maximum Output Frequency is
60Hz, the Maximum Output Frequency will be limited to 50Hz.
! If the Lower Bound of Output Frequency is 10Hz, and the Minimum Output Frequency
(Pr.1-05) is set at 1.0Hz, then any Command Frequency between 1-10Hz will generate
a 10Hz output from the drive.
! This parameter must be equal to or less than the Upper Bound of Output Frequency
(Pr.1-07).
Kommentare zu diesen Handbüchern