Seitenansicht 72
VFD-S Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-56
3.5 Address list:
The contents of available addresses are shown as below:
Tartalom
Tár cím
Funkciók
AC drive
Parameters
ggnnH gg means parameter group, nn means parameter number, for
example, the address of Pr 4-01 is 0401H. Referencing to
chapter 5 for the function of each parameter. When reading
parameter by command code 03H, only one parameter can
be read at one time.
Bit 0-1 00: No function
01: Stop
10: Run
11: Jog + Run
Bit 2-3 Not used
Bit 4-5
00: No function
01: FWD
10: REV
11: Change direction
2000H
Bit 6-15 Not used
2001H Freq. command
Bit 0 1: EF (external fault) on
Bit 1 1: Reset
Command
2002H
Bit 2-15 Not used
Status monitor
Read only
2100H Error code:
0: No errors occurred
1: Over-current (oc)
2: Over-voltage (ov)
3: Overheat (oH)
5: Overload1 (oL1)
6: External fault (EF)
7: Not used
8: Not used
9: Current exceeds 2 times rated current during acceleration
(ocA)
10: Current exceeds 2 times rated current during deceleration
(ocd)
11: Current exceeds 2 times rated current during steady state
operation (ocn)
12: Ground Fault (GF)
13: Reserved
14: Low voltage (Lv)
15: CPU failure 1 (cF1)
16: CPU failure 2 (cF2)
17: Base block
18: Overload (oL2)
19: Auto acceleration/deceleration failure (cFA)
20: Software protection enable (codE)