Delta Electronics AC Drive VFD-F Series Spezifikationen Seite 156

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 190
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 155
VFD-F Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
8-16
Parameters Functions Settings
Factory
Setting
Customer
06-18 Recording Mid/Low Voltage
while running the AC Drive
00: None recorded low voltage,
parameter reset automatically
01: None recorded low voltage,
parameter reset manually
02: Recorded low voltage, parameter
reset manually
00
Group 7 AC Drive and Motor Parameters
Parameters Functions Settings
Factory
Setting
Customer
07-00 Identity Code of AC Drive Display by model type
##
07-01 Rated Current of AC Drive Display by model type
##
07-02 Full-load Current of Motor 30~120% 100%
07-03 No-load Current of Motor 1~99% 30%
07-04 Auto Slip Compensation Gain 0.0~3.0 0.0
07-05 Rated Slip Frequency of Motor 0.00~20.00Hz 0.00
07-06 Auto Torque Compensation Gain 0.0~10.0 0.0
07-07 Torque Compensation Gain by
Manually
0.0~10.0 0.0
07-08 Calculate Total Running Time of
the Motor (Min)
00 to 1439 Min 00
07-09 Calculate Total Running Time of
the Motor (Day)
00 to 65535 Day 00
07-10 Poles of Motors 2~10 4
07-11 Reserved
Seitenansicht 155
1 2 ... 151 152 153 154 155 156 157 158 159 160 161 ... 189 190

Kommentare zu diesen Handbüchern

Keine Kommentare